{"title":"CAN EGT - CAN EGT","description":null,"products":[{"product_id":"exhaust-gas-temperature-probe-egt","title":"Link Engine Management Exhaust Gas Temperature Probe (EGT)","description":"\u003ch2 class=\"product-details-information-tab-content-panel-title\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-type=\"information-content-text\" class=\"product-details-information-tab-content-container\" id=\"product-details-information-tab-content-container-0\"\u003e\n\u003cp\u003eExtreme Duty Fast Response EGT Temperature Probe \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType K thermocouple probe\u003c\/li\u003e\n\u003cli\u003eExposed sensing junction for fastest response\u003c\/li\u003e\n\u003cli\u003eIncludes 316 SS adjustable compression fitting\u003c\/li\u003e\n\u003cli\u003eStainless steel protected wires\u003c\/li\u003e\n\u003cli\u003eDesigned for extreme engine test \u0026amp; racing environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003eWhen using this with an ECU other than the Thunder, you will need to use an amplifier.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThermocouple type: K\u003cbr\u003eRange: -148 to 2372°F (-100 to 1300°C)\u003cbr\u003eAccuracy: +\/-0.4% of reading or about +\/- 1.1°C (Special Limits of Error)\u003cbr\u003eProbe diameter: 1\/4 inch (0.250 inch) (6.35 mm)\u003cbr\u003eSensing Junction: Exposed, Ungrounded\u003cbr\u003eResponse Time*: 150 mS\u003cbr\u003e*Time Constant: Defined as the time required to reach 63.2% of an instantaneous temperature change\u003cbr\u003eFive time constants are required to approach 100% of the step change value\u003cbr\u003eOuter Sheath Material: Inconel, melting point 2550°F (1400°C)\u003cbr\u003eCable: Stainless steel overbraiding over Teflon™ insulated, stranded wires, 20 gauge. 6ft \/ 1.8m in length.\u003cbr\u003eCompression Fitting: 316 stainless steel, adjustable, 1\/8 inch –27 NPT male thread\u003cbr\u003e\u003cbr\u003eWiring: + = Yellow – = Red\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Link Engine Management","offers":[{"title":"Default Title","offer_id":48738540978400,"sku":"LEM-101-0146","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1003\/2430\/files\/media_4949f473-ed9c-4cd7-a29c-e775fbfabe1f.jpg?v=1770326763"},{"product_id":"tcc04-4-channel-egt-to-can-module","title":"Link Engine Management TCC04 4 Channel EGT to CAN Module","description":"\u003ch3\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eLink TCC04 4 Channel EGT to CAN module, powered by CANchecked \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eThe TCC04 EGT to CAN module allows you to connect up to four Type-K thermocouples and send the values via CAN bus and\/or monitor them directly on your wireless enabled device. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eType-K thermocouples are suitable for various applications such as measuring exhaust gas temperature (EGT), temperatures before\/after the intercooler, turbo housings, cylinder head temperatures, water temperature, oil temperature and more. All measurements are cold junction compensated with a measuring range of 0 to 1250°C in 0.25°C resolution (14bit). \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eThe TCC04 feature a four-pin DTM connector for CAN\/power and miniature K-sockets. It is pin compatible with Links standard CAN pinout and CAN cables range. CAN 2.0A\/B standard is supported with flexible configuration.  \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eWireless connectivity allows you to configure and update your module via smartphone or PC and query the current temperature and thermocouple status. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e-    4 x cold junction compensated type-K inputs       \u003cbr\u003e-    Four-pin DTM connector \u0026amp; miniature K-sockets.   \u003cbr\u003e-    CAN Bus connection to ECU (Pre-Configured for Link ECU)       \u003cbr\u003e-    Measuring range from 0 to 1250°C (32 to 2282°F) with 0.25°C resolution       \u003cbr\u003e-    Detection of short circuit to ground or if no type-K is connected       \u003cbr\u003e-    Standard mini k thermocouple connector       \u003cbr\u003e-    Full configuration and monitoring over wireless     \u003cbr\u003e-    Adjustable sample frequency up to 100Hz\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eBox Contents:  \u003c\/strong\u003e\u003cbr\u003e1 x CAN EGT Module       \u003cbr\u003e1 x DTM4 Mating Connector Kit        \u003cbr\u003e2 x Link Stickers       \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/kb.linkecu.com\/acc-kb\/latest\/link-tccxx\"\u003eSet-Up and Installation Guide \u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDTM 4 CAN Pinout (Supports Links CAN pinout schema and CAN cables range)\u003c\/li\u003e\n\u003cli\u003ePin 1: 12V Pin 2: Ground Pin 3: Can Low Pin 4: Can High\u003c\/li\u003e\n\u003cli\u003eAccuracy: maximum 2% deviation\u003c\/li\u003e\n\u003cli\u003eDimension (L x W x H) – 97.3 x 31.5 x 34.6mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Options:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module can be configured via wireless:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCan Speed: 125kbps, 250kbps, 500kbps, 1Mbps\u003c\/li\u003e\n\u003cli\u003eEmulation: Standard, All major aftermarket EGT\/Thermocouple to CAN Modules\u003c\/li\u003e\n\u003cli\u003eChange of standard Can Bus ID\u003c\/li\u003e\n\u003cli\u003eChange Big\/Little Endian\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/kb.linkecu.com\/acc-kb\/latest\/link-tccxx\"\u003eSet-Up and Installation Guide \u003c\/a\u003e\u003c\/p\u003e","brand":"Link Engine Management","offers":[{"title":"Default Title","offer_id":48738557264096,"sku":"LEM-101-0384","price":280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1003\/2430\/files\/media_5b32ef4a-4c07-43cf-9a5f-b0423eab0415.jpg?v=1770327200"},{"product_id":"tcc08-8-channel-egt-to-can-module","title":"Link Engine Management TCC08 8 Channel EGT to CAN Module","description":"\u003ch3\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eLink TCC08 8 Channel EGT to CAN module, powered by CANchecked\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe TCC08 EGT to CAN module allows you to connect up to eight Type-K thermocouples and send the values via CAN bus and\/or monitor them directly on your wireless enabled device.    \u003cbr\u003e\u003cbr\u003eType-K thermocouples are suitable for various applications such as measuring exhaust gas temperature (EGT), temperatures before\/after the intercooler, turbo housings, cylinder head temperatures, water temperature, oil temperature and more. All measurements are cold junction compensated with a measuring range of 0 to 1250°C in 0.25°C resolution (14bit).    \u003cbr\u003e\u003cbr\u003eThe TCC08 features a four-pin DTM connector for CAN\/power and miniature K-sockets. It is pin compatible with Links standard CAN pinout and CAN cables range. CAN 2.0A\/B standard is supported with flexible configuration.     \u003cbr\u003e\u003cbr\u003eWireless connectivity allows you to configure and update your module via smartphone or PC and query the current temperature and thermocouple status.     \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e8 x cold junction compensated type-K inputs\u003c\/li\u003e\n\u003cli\u003eFour-pin DTM connector \u0026amp; miniature K-sockets. \u003c\/li\u003e\n\u003cli\u003eCAN Bus connection to ECU (Pre-Configured for Link ECU)\u003c\/li\u003e\n\u003cli\u003eMeasuring range from 0 to 1250°C (32 to 2282°F) with 0.25°C resolution\u003c\/li\u003e\n\u003cli\u003eDetection of short circuit to ground or if no type-K is connected\u003c\/li\u003e\n\u003cli\u003eStandard mini k thermocouple connector\u003c\/li\u003e\n\u003cli\u003eFull configuration and monitoring over wireless \u003c\/li\u003e\n\u003cli\u003eAdjustable sample frequency up to 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBox Contents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1 x CAN EGT Module\u003c\/p\u003e\n\u003cp\u003e1 x DTM4 Mating Connector Kit\u003c\/p\u003e\n\u003cp\u003e2 x Link Stickers\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/kb.linkecu.com\/acc-kb\/latest\/link-tccxx\"\u003e\u003cstrong\u003eSet-up and Installation Guide\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDTM 4 CAN Pinout (Supports Links CAN pinout schema and CAN cables range) \u003cbr\u003ePin 1: 12V Pin 2: Ground Pin 3: Can Low Pin 4: Can High\u003c\/li\u003e\n\u003cli\u003eAccuracy: maximum 2% deviation \u003c\/li\u003e\n\u003cli\u003eDimension (L x W x H) – 129 x 31.5 x 34.6mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConfiguration Options:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module can be configured via wireless:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCan Speed: 125kbps, 250kbps, 500kbps, 1Mbps\u003c\/li\u003e\n\u003cli\u003eEmulation: Standard, All major aftermarket EGT\/Thermocouple to CAN Modules\u003c\/li\u003e\n\u003cli\u003eChange of standard Can Bus ID\u003c\/li\u003e\n\u003cli\u003eChange Big\/Little Endian\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/kb.linkecu.com\/acc-kb\/latest\/link-tccxx\"\u003e\u003cstrong\u003eSet-up and Installation Guide\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Link Engine Management","offers":[{"title":"Default Title","offer_id":48738557460704,"sku":"LEM-101-0388","price":335.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1003\/2430\/files\/media_20ce0c74-3816-4c8b-9029-7bb2fa758293.jpg?v=1770327203"},{"product_id":"4-x-exhaust-gas-temperature-probe-bundle-egts","title":"Link Engine Management 4 x Exhaust Gas Temperature Probe Bundle (EGTs)","description":"\u003ch3\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eExtreme Duty Fast Response EGT Temperature Probe. \u003c\/p\u003e\n\u003cp\u003eThis bundle includes four EGTs. \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType K thermocouple probe\u003c\/li\u003e\n\u003cli\u003eExposed sensing junction for fastest response\u003c\/li\u003e\n\u003cli\u003eIncludes 316 SS adjustable compression fitting\u003c\/li\u003e\n\u003cli\u003eStainless steel protected wires\u003c\/li\u003e\n\u003cli\u003eDesigned for extreme engine test \u0026amp; racing environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThermocouple type: K\u003cbr\u003eRange: -148 to 2372°F (-100 to 1300°C)\u003cbr\u003eAccuracy: +\/-0.4% of reading or about +\/- 1.1°C (Special Limits of Error)\u003cbr\u003eProbe diameter: 1\/4 inch (0.250 inch) (6.35 mm)\u003cbr\u003eSensing Junction: Exposed, Ungrounded\u003cbr\u003eResponse Time*: 150 mS\u003cbr\u003e*Time Constant: Defined as the time required to reach 63.2% of an instantaneous temperature change\u003cbr\u003eFive time constants are required to approach 100% of the step change value\u003cbr\u003eOuter Sheath Material: Inconel, melting point 2550°F (1400°C)\u003cbr\u003eCable: Stainless steel overbraiding over Teflon™ insulated, stranded wires, 20 gauge. 6ft \/ 1.8m in length.\u003cbr\u003eCompression Fitting: 316 stainless steel, adjustable, 1\/8 inch –27 NPT male thread\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e+ = Yellow\u003c\/p\u003e\n\u003cp\u003e– = Red\u003c\/p\u003e","brand":"Link Engine Management","offers":[{"title":"Default Title","offer_id":48738558542048,"sku":"LEM-101-0146 - 4Bundle","price":550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1003\/2430\/files\/media_e7d3bd82-6167-448e-afb9-84de95c1c0fd.jpg?v=1770327211"},{"product_id":"8-x-exhaust-gas-temperature-probe-bundle-egts","title":"Link Engine Management 8 x Exhaust Gas Temperature Probe Bundle (EGTs)","description":"\u003ch3\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eExtreme Duty Fast Response EGT Temperature Probe. \u003c\/p\u003e\n\u003cp\u003eBundle includes 8 x Probes. \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType K thermocouple probe\u003c\/li\u003e\n\u003cli\u003eExposed sensing junction for fastest response\u003c\/li\u003e\n\u003cli\u003eIncludes 316 SS adjustable compression fitting\u003c\/li\u003e\n\u003cli\u003eStainless steel protected wires\u003c\/li\u003e\n\u003cli\u003eDesigned for extreme engine test \u0026amp; racing environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThermocouple type: K\u003cbr\u003eRange: -148 to 2372°F (-100 to 1300°C)\u003cbr\u003eAccuracy: +\/-0.4% of reading or about +\/- 1.1°C (Special Limits of Error)\u003cbr\u003eProbe diameter: 1\/4 inch (0.250 inch) (6.35 mm)\u003cbr\u003eSensing Junction: Exposed, Ungrounded\u003cbr\u003eResponse Time*: 150 mS\u003cbr\u003e*Time Constant: Defined as the time required to reach 63.2% of an instantaneous temperature change\u003cbr\u003eFive time constants are required to approach 100% of the step change value\u003cbr\u003eOuter Sheath Material: Inconel, melting point 2550°F (1400°C)\u003cbr\u003eCable: Stainless steel overbraiding over Teflon™ insulated, stranded wires, 20 gauge. 6ft \/ 1.8m in length.\u003cbr\u003eCompression Fitting: 316 stainless steel, adjustable, 1\/8 inch –27 NPT male thread\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e+ = Yellow\u003c\/p\u003e\n\u003cp\u003e– = Red\u003c\/p\u003e","brand":"Link Engine Management","offers":[{"title":"Default Title","offer_id":48738558574816,"sku":"LEM-101-0146 - 8Bundle","price":1100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1003\/2430\/files\/media_d4d4a99c-c28b-4eab-95cc-cdd6302df535.jpg?v=1770327214"},{"product_id":"tcc06-6-channel-egt-to-can-module","title":"Link Engine Management TCC06 6 Channel EGT to CAN Module","description":"\u003ch3\u003e\u003cstrong\u003eLink TCC06 6 Channel EGT to CAN module, powered by CANchecked \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003eThe TCC06 EGT to CAN module allows you to connect up to six Type-K thermocouples and send the values via CAN bus and\/or monitor them directly on your wireless enabled device. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eType-K thermocouples are suitable for various applications such as measuring exhaust gas temperature (EGT), temperatures before\/after the intercooler, turbo housings, cylinder head temperatures, water temperature, oil temperature and more. All measurements are cold junction compensated with a measuring range of 0 to 1250°C in 0.25°C resolution (14bit). \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eThe TCC06 feature a four-pin DTM connector for CAN\/power and miniature K-sockets. It is pin compatible with Links standard CAN pinout and CAN cables range. CAN 2.0A\/B standard is supported with flexible configuration.  \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eWireless connectivity allows you to configure and update your module via smartphone or PC and query the current temperature and thermocouple status. \u003c\/p\u003e\n\u003ch3\u003e\n\u003cbr\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e-    6 x cold junction compensated type-K inputs      -    Four-pin DTM connector \u0026amp; miniature K-sockets.  \u003cbr\u003e-    CAN Bus connection to ECU (Pre-Configured for Link ECU)      \u003cbr\u003e-    Measuring range from 0 to 1250°C (32 to 2282°F) with 0.25°C resolution      \u003cbr\u003e-    Detection of short circuit to ground or if no type-K is connected      \u003cbr\u003e-    Standard mini k thermocouple connector      \u003cbr\u003e-    Full configuration and monitoring over wireless    \u003cbr\u003e-    Adjustable sample frequency up to 100Hz\u003c\/p\u003e\n\u003ch3\u003e\n\u003cbr\u003e\u003cstrong\u003eBox Contents:  \u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e1 x CAN EGT Module      \u003cbr\u003e1 x DTM4 Mating Connector Kit       \u003cbr\u003e2 x Link Stickers      \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/kb.linkecu.com\/acc-kb\/latest\/link-tccxx\"\u003eSet-Up and Installation Guide \u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDTM 4 CAN Pinout (Supports Links CAN pinout schema and CAN cables range)\u003c\/li\u003e\n\u003cli\u003ePin 1: 12V Pin 2: Ground Pin 3: Can Low Pin 4: Can High\u003c\/li\u003e\n\u003cli\u003eAccuracy: maximum 2% deviation\u003c\/li\u003e\n\u003cli\u003eDimension (L x W x H) – 97.3 x 31.5 x 34.6mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Options:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module can be configured via wireless:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCan Speed: 125kbps, 250kbps, 500kbps, 1Mbps\u003c\/li\u003e\n\u003cli\u003eEmulation: Standard, All major aftermarket EGT\/Thermocouple to CAN Modules\u003c\/li\u003e\n\u003cli\u003eChange of standard Can Bus ID\u003c\/li\u003e\n\u003cli\u003eChange Big\/Little Endian\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/kb.linkecu.com\/acc-kb\/latest\/link-tccxx\"\u003eSet-Up and Installation Guide \u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Link Engine Management","offers":[{"title":"Default Title","offer_id":48738558869728,"sku":"LEM-101-0386","price":305.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1003\/2430\/files\/media_0e9cf1c7-311f-4bfe-b3c4-4c0139f6e7db.jpg?v=1770327222"},{"product_id":"6-x-exhaust-gas-temperature-probe-bundle-egts","title":"Link Engine Management 6 x Exhaust Gas Temperature Probe Bundle (EGTs)","description":"\u003cp\u003e\u003cstrong\u003eExtreme Duty Fast Response EGT Temperature Probe. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBundle includes 6 x Probes. \u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType K thermocouple probe\u003c\/li\u003e\n\u003cli\u003eExposed sensing junction for fastest response\u003c\/li\u003e\n\u003cli\u003eIncludes 316 SS adjustable compression fitting\u003c\/li\u003e\n\u003cli\u003eStainless steel protected wires\u003c\/li\u003e\n\u003cli\u003eDesigned for extreme engine test \u0026amp; racing environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThermocouple type: \u003c\/strong\u003eK\u003cbr\u003eRange: -148 to 2372°F (-100 to 1300°C)\u003cbr\u003eAccuracy: +\/-0.4% of reading or about +\/- 1.1°C (Special Limits of Error)\u003cbr\u003eProbe diameter: 1\/4 inch (0.250 inch) (6.35 mm)\u003cbr\u003eSensing Junction: Exposed, Ungrounded\u003cbr\u003eResponse Time*: 150 mS\u003cbr\u003e*Time Constant: Defined as the time required to reach 63.2% of an instantaneous temperature change\u003cbr\u003eFive time constants are required to approach 100% of the step change value\u003cbr\u003eOuter Sheath Material: Inconel, melting point 2550°F (1400°C)\u003cbr\u003eCable: Stainless steel overbraiding over Teflon™ insulated, stranded wires, 20 gauge. 6ft \/ 1.8m in length.\u003cbr\u003eCompression Fitting: 316 stainless steel, adjustable, 1\/8 inch –27 NPT male thread\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e+ = Yellow\u003c\/p\u003e\n\u003cp\u003e– = Red\u003c\/p\u003e","brand":"Link Engine Management","offers":[{"title":"Default Title","offer_id":48738559099104,"sku":"LEM-101-0146 - 6Bundle","price":825.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1003\/2430\/files\/101-0146-6Bundle.0.avif?v=1771374749"}],"url":"https:\/\/www.edoperformance.com\/collections\/can-egt-can-egt.oembed","provider":"EDO Performance","version":"1.0","type":"link"}